Energy Hub / Field Lab 01 / Energy planning

Will your power
last the outage?

Start with what you need to keep running. Then see what your battery and solar can actually cover under your assumptions.

Field guide: Workshop notes

The field smith: Measure twice, pack once. Example equipment is a starting point. Use your own measurements; an energy estimate cannot verify startup power, electrical compatibility or critical medical continuity.

HTML is the offline app. JSON is a portable backup of your settings. Save My Setup keeps a separate kit snapshot; automatic browser recovery protects your working session only. Inventory changes never silently update scenario snapshots.

The example gives you somewhere to start. Swap in measurements from your own equipment when you have them. This is an energy estimate, not a check of startup power, electrical compatibility, or critical medical continuity.

Calculating your scenario…View results ↓

Export current working setup?

Your working setup differs from the explicitly saved Field Kit setup. This export can include the current working values.

Download Offline Tool gives you a clean HTML app. Download With My Setup includes everything entered here. Both work without a connection.

HTML is the app you can open offline. JSON is a backup of your setup.

Save My Setup keeps a separate copy for your Field Kit. Export JSON saves a portable data file.

Reset or clear browser copies

Reset example replaces the working session with sample inputs. Clear working session removes its browser copy; editing starts autosave again. Neither changes your saved Kit setup.

Armory equipment

Load inventory to see available equipment.

Expand Armory linking and transfers

Choose one physical unit from an inventory entry. Values are copied into this scenario, never synchronized automatically. Existing equipment stays in place. Remove example equipment you do not own. New appliances start at zero operating hours; set their schedule in Energy.


Separate files exchange inventory JSON. In a combined kit, Armory belongs to the active kit profile. The hosted site uses the active Armory inventory profile; Energy remains its existing independent working scenario.

Review missing equipment

Adjust outage duration, weather and yield assumptions

Daily yield is the fraction of baseline daily solar energy retained after weather adjustment, not an instantaneous percentage of panel watts. Baseline = panel W × peak-sun hours × production retained. Input limits and charging losses apply separately. Keep peak-sun hours and production retained in Shared sunlight assumptions below.

Tap or click a day to cycle through Sunny, Partly cloudy, Overcast, and Rainout. Use Enter or Space when focused. Rainout forces solar production to 0% for that day. Each day is a 24-hour block from the outage start. Weather factors are selected scenarios, not forecasts or validated climate averages. If your peak-sun-hours input already includes cloud losses, use Sunny to avoid counting them twice.

Sustainability & resilience

Can it last the outage, and keep going?

Review candidate

Inspect reserve trajectories

Battery reserve projection

Above reserve · Wh
Configured outageRepeated assumptionsReserve boundaryRed dotted: first unmet demandBlue dashed: first reserve touchBrown: selected station
Projected station values at this hour
Sum of usable energy across independent stations, not a transferable pool. Dashed continuation repeats the selected weather sequence; it is not a future weather forecast. Zero means the chosen reserve boundary.

Energy supplied & unserved

Wh per outage day
Energy suppliedEnergy unserved (hatched)
Stacked total = required energy at the battery bus, including conversion and idle requirements. Stored battery energy and solar supply the served portion.
Daily supplied and unserved values
Solar collected and spilled

Detailed energy accounting

Potential solar = clipped + charging loss + accepted solar. Accepted solar = used directly or stored + spill. Do not add potential, accepted and used values together. Required energy and unmet bus demand include conversion and idle requirements; unmet appliance demand is measured separately at outputs. Net = accepted solar minus required energy, before spill. Storage can bridge a negative balance.

External replenishment

Weather resilience

Station exhaustion & load allocation

Try reassigning a compatible appliance using its station selector below, then compare results. Check AC/DC ports, running and surge power, voltage and connector compatibility first. This model has no automatic switching or station-to-station transfer. Solar stays with its assigned station; moving loads does not remove a system-wide generation deficit.

Daily values & analysis assumptions

All balances use the battery-bus boundary. Approximately balanced means within the larger of 1 Wh/day or 1% of required daily energy; this display tolerance never changes the simulation. Depletion means the first hourly interval with unmet appliance demand and energy at or below reserve. A reserve touch with no unmet demand is reported separately. Hourly intervals do not establish an exact shutdown minute.

Projections repeat the configured daily weather pattern and appliance schedules for up to 365 days, retaining charge, reserve, losses and station limits. Surplus does not guarantee continuous service. Three rainout days are a separate sensitivity starting at your entered charge, not a probability estimate. Fuel-backed generation and fuel-use rates are not modeled.

Add your appliances, assign a station, then edit their energy use and daily schedule.

Primary battery

Units are pooled energy from a compatible system, not instructions to wire separate stations together. Reserve is energy you choose to keep; inaccessible capacity is a separate Advanced setting. How the model works.

Independent stations have separate energy budgets. Removing a station reassigns its loads and sources to the primary station.

Shared sunlight assumptions

Each physical array must be entered once and assigned to one station. Station input caps apply to the combined arrays feeding that station. Generator, grid charging, source switching and station-to-station charging are not modeled.

Primary station assumptions and limits

Defaults are selected estimates, not class averages or specifications. Check the exact station manual and representative measurements. Efficiencies below exclude the separately modeled idle drain.

Otherwise idle draw is counted only in hours with AC demand, including averaged cycling loads. At a shortfall, demand, losses, and idle draw are served proportionally. No automatic priority or real restart behavior is implied.

Use 100% accessible capacity if your capacity input already represents the accessible battery-side amount. This is not measured outlet capacity: entering delivered AC Wh and applying inverter losses again would double-count them. Do not use a whole-system efficiency that already includes idle draw with another idle penalty.

The discharge cap is battery-side power, not an inverter output rating. This model does not check per-port ratings, surge, volts, amps, power factor, charge taper, temperature lockouts, or wiring compatibility. Basic mode keeps these advanced defaults in force.

Separate inverter check for the selected station

This conservative check assumes all entered AC running loads overlap, without duty-cycle averaging. Daily-energy-only loads have unknown running power. Startup surge, power factor and port limits still require equipment specifications and testing. This check does not change the energy simulation. The entered rating applies to the station selected in the results below.

The energy picture.

SunnyPartly cloudyOvercastRainout · 0%
Solid line: modeled state of charge. Dashed line: chosen reserve. Background: sunny, partly cloudy, overcast, or zero-solar rainout scenario. Exact hourly accounting is available below.
Inspect hourly energy accounting

All energy columns are Wh. Solar potential is before input clipping; input and charging losses precede the battery bus. Spill is excess at the bus. Served demand is at the outlets.

Export JSON keeps your inputs. CSV downloads the hourly results separately.
Methodology, equations and limitations

Model notes / Read the boundaries

Follow the energy.

Appliances: Wh = watts × operating hours. Cycling Wh = hours × [on watts × duty fraction + off watts × (1 − duty fraction)]. A measured daily total replaces this estimate and is spread evenly over 24 hours. Do not add a defrost allowance twice if the measurement includes it.

Multiple stations: Each independent station is simulated separately using the existing hourly model. Appliances are assigned to exactly one station. Solar watts are allocated rather than duplicated. Select a station for its graph and detailed ledger. The CSV includes every station, labeled by ID and name. Automatic load switching, inter-station transfer, and shared charging are not modeled.

Schedules: Multiple operating windows can cross midnight and use fractional hours. Overlapping windows are merged so one appliance is never counted twice. Older start-hour / duration entries remain the fallback until edited. Daily-energy mode spreads measured Wh uniformly and ignores windows.

Battery: maximum Wh = nominal Wh × units × accessible fraction. Initial Wh = maximum × initial state of charge. Reserve Wh = maximum × reserve fraction. Available energy above reserve = max(0, initial Wh − reserve Wh). Starting below reserve is allowed; it does not create energy, and discharge waits until charging lifts the battery above reserve.

Loads at the battery bus: AC Wh ÷ AC efficiency + DC Wh ÷ DC efficiency + active inverter idle Wh. AC and DC losses are applied once. Device demand should be measured at the selected output, not the internal device battery. Additional DC/shared control overhead is not modeled.

Solar is a daily energy scenario

Daily potential input Wh = panel W × baseline peak-sun hours × retained production fraction × weather factor. This energy is spread across a fixed 06:00–18:00 daylight window. Each hour is capped by the maximum input W before charging efficiency is applied. This rectangular curve preserves the daily integral, but understates noon peaks and can understate clipping. It is not a location, season, shading, or MPPT model.

Each hour: solar serves the common bus first; the battery supplies remaining demand, subject to reserve and discharge limits. Excess solar charges available capacity, then spills. The charging conversion factor applies once to all accepted solar input, including concurrent loads. This is a simplified common-bus architecture; actual station paths vary.

start Wh + solar input Wh = end Wh + served load Wh + load conversion loss Wh + idle Wh + charge loss Wh + spill Wh

Panel potential = accepted solar input + clipping. Unmet demand is reported at the load boundary and is not subtracted from the battery. The first failure is reported as a one-hour interval, not an exact shutdown minute. Later solar recovery does not erase an earlier failure.

What to measure next

Measure refrigeration over representative cycles, not just a compressor’s running watts. Confirm AC idle consumption and actual usable capacity at a comparable load. Compare several poor-weather days. Reducing continuous demand saves energy every hour, including overnight when more panels cannot help.

Matching the energy budget does not establish that equipment will start or remain available. Medical loads require a device-specific continuity plan; this illustrative profile is not a clinical recommendation. Refrigerator energy estimates do not establish food-safe temperatures.

◈ Workshop milestones Optional / local to this browser

A small record of things you’ve tried here. Milestones don’t certify safety, equipment compatibility, or real-world readiness.

    Enable JavaScript to view local milestones.

    Tools download individually for now. A combined Field Kit can have its milestone when it actually works.

    Read the research

    The battery and solar source reviews are awaiting editorial review. See their status in Research. The model equations and limitations are documented above.